Safety Inspection Of Tower Cranes During Daily Use

May 09, 2024

Leave a message

Tower cranes must be inspected before and after installation and during daily use. Metal structure welds must not crack, metal structures must not be plastically deformed, the quality of connecting bolts and pins must meet the requirements, and measures to prevent retreat and loosening must be taken. Personnel must be arranged to pre-tighten the connecting bolts regularly, the wire rope must be lubricated and well maintained, the number of broken wires must not exceed the standard, broken strands must not be allowed, plastic deformation must not be allowed, the rope clamp joints must meet the standards, the reduction box and oil cylinder must not leak oil, the hydraulic system pressure must be normal, the brake and limit insurance must be sensitive and reliable, the transmission mechanism must be well lubricated, the safety devices must be complete and reliable, and the electrical control circuit must be well insulated. In particular, tower crane drivers, maintenance electricians, and mechanical maintenance workers must be urged to conduct regular inspections, especially to check the wire rope, hook, various transmission parts, limit insurance devices and other vulnerable parts, and immediately deal with problems when they are found, so as to assign personnel, time, and measures to strictly prevent mechanical operation with defects.

Send Inquiry